poe(ubiquiti): UDB-Pro and F-POE-G2 source upstream watts, and one had been citing a page with no product #2507

Merged
jaylouisw merged 1 commit from catalogue/1124-0122 into main 2026-11-24 01:39:37 +00:00
Owner

No open device-request issue exists (all 50 are closed), so this is step 2 of docs/plans/poe-budget-variants.md: mark the boxes whose ceiling belongs to something plugged into them, and leave the figure absent rather than subtract one.

The two files

devices/ubiquiti/udb-pro.json — poe.passthrough: true. The passive output on eth1 has no supply of its own. Ubiquiti's table: Power Method: PoE / PoE+ (Required for PoE output) and Management: (1) PoE in (PoE output not used) / (1) Passive PoE output (https://techspecs.ui.com/unifi/wifi/udb-pro, HTTP 200, 628,754 B, read 2026-11-24). No wattage is printed for the output; the page's only figures are the included 48V, 0.32A adapter (15.4 W into the box) and Max. Power Consumption: 9W. The page never uses the word "passthrough" — the PoE+ input requirement is what makes it one, and that line is in the spec's poe.note.

devices/ubiquiti/f-poe-g2.json — poe.passthrough: true, plus a sourceUrl correction. The old URL ended ...outdoor-poe-d and 307s to the techspecs home page (no product), so the spec had been citing a page that describes nothing. The path with the slug intact is https://techspecs.ui.com/uisp/fiber/optical-data-transport-for-outdoor-poe-devices (HTTP 200, 587,458 B, read 2026-11-24), and its Power Method row uses the vendor's own word: 4-pair (24V DC/50V DC input) passthrough / PoE RJ45 port ... PoE passthrough. Its power figures are inputs or its own draw — Input DC voltage: 16-57V, Power Consumption: 1.5W (Typical), DC Output: Terminal block, 24V DC/50V DC, 2-wire — none a PSE ceiling.

The other two boxes step 2 named had already left the cohort through their own sheets: planet/POE-E201 by budgetW: 26 (#2487) and ubiquiti/UACC-LR-Endpoint by budgetW: 60 (#2495), because both vendors print a figure for the outlet.

Audit, before → after

Silent: 2 → 0
Passthrough: 0 → 2   ubiquiti/UDB-Pro (1 PSE), ubiquiti/F-POE-G2 (1 PSE)
Contradictory passthrough declarations: 0
node scripts/audit-poe-budget.js --strict: exit 1 → exit 0

The engine is untouched. These ports still serve 0 W — no allocation rule reads passthrough — so the flag buys an honest audit line, not working power. Step 3 (the package.json gate) is now unblocked; step 5 (docs/DEVICE_SCHEMA.md) is the next thing owed, because two files now set a field the schema does not define.

Gates

syntax 560 files OK · audit-port-types gated 0 · audit-devices gated 0 · hardware-invariants 26/26 · test/poe-budget-gate.test.js 18 assertions · importer dry-run unchanged (its exit 1 reproduces on baseline, from pre-existing research/incoming warnings) · full run 475/476, the one red being canonical-urls' dirty-README flake, green standalone 86/86 · registry doc current (2,352 models, no port change).

No open device-request issue exists (all 50 are closed), so this is step 2 of `docs/plans/poe-budget-variants.md`: mark the boxes whose ceiling belongs to something plugged into them, and leave the figure absent rather than subtract one. ## The two files **`devices/ubiquiti/udb-pro.json`** — `poe.passthrough: true`. The passive output on `eth1` has no supply of its own. Ubiquiti's table: `Power Method: PoE / PoE+ (Required for PoE output)` and `Management: (1) PoE in (PoE output not used) / (1) Passive PoE output` (https://techspecs.ui.com/unifi/wifi/udb-pro, HTTP 200, 628,754 B, read 2026-11-24). No wattage is printed for the output; the page's only figures are the included `48V, 0.32A` adapter (15.4 W *into* the box) and `Max. Power Consumption: 9W`. The page never uses the word "passthrough" — the PoE+ input requirement is what makes it one, and that line is in the spec's `poe.note`. **`devices/ubiquiti/f-poe-g2.json`** — `poe.passthrough: true`, plus a `sourceUrl` correction. The old URL ended `...outdoor-poe-d` and 307s to the techspecs home page (no product), so the spec had been citing a page that describes nothing. The path with the slug intact is https://techspecs.ui.com/uisp/fiber/optical-data-transport-for-outdoor-poe-devices (HTTP 200, 587,458 B, read 2026-11-24), and its Power Method row uses the vendor's own word: `4-pair (24V DC/50V DC input) passthrough / PoE RJ45 port ... PoE passthrough`. Its power figures are inputs or its own draw — `Input DC voltage: 16-57V`, `Power Consumption: 1.5W (Typical)`, `DC Output: Terminal block, 24V DC/50V DC, 2-wire` — none a PSE ceiling. The other two boxes step 2 named had already left the cohort through their own sheets: `planet/POE-E201` by `budgetW: 26` (#2487) and `ubiquiti/UACC-LR-Endpoint` by `budgetW: 60` (#2495), because both vendors print a figure for the outlet. ## Audit, before → after ``` Silent: 2 → 0 Passthrough: 0 → 2 ubiquiti/UDB-Pro (1 PSE), ubiquiti/F-POE-G2 (1 PSE) Contradictory passthrough declarations: 0 node scripts/audit-poe-budget.js --strict: exit 1 → exit 0 ``` **The engine is untouched.** These ports still serve 0 W — no allocation rule reads `passthrough` — so the flag buys an honest audit line, not working power. Step 3 (the `package.json` gate) is now unblocked; step 5 (`docs/DEVICE_SCHEMA.md`) is the next thing owed, because two files now set a field the schema does not define. ## Gates syntax 560 files OK · audit-port-types gated 0 · audit-devices gated 0 · hardware-invariants 26/26 · `test/poe-budget-gate.test.js` 18 assertions · importer dry-run unchanged (its exit 1 reproduces on baseline, from pre-existing `research/incoming` warnings) · full run 475/476, the one red being `canonical-urls`' dirty-README flake, green standalone 86/86 · registry doc current (2,352 models, no port change).
poe(ubiquiti): the last two silent PSEs source upstream watts, and one cited a page with no product
All checks were successful
CI / Typecheck (pull_request) Successful in 18s
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 9s
CI / Server smoke and Docker build (pull_request) Successful in 36s
CI / Test (Node 22) (pull_request) Successful in 53s
CI / Test (Node 24) (pull_request) Successful in 59s
CI / Arm auto-merge (pull_request) Successful in 4s
7e82e400ba
The device-request queue is empty, so this is step 2 of
docs/plans/poe-budget-variants.md: mark the boxes whose PoE budget belongs to
something plugged into them, and leave the figure absent rather than subtract one.

ubiquiti/UDB-Pro (devices/ubiquiti/udb-pro.json) - poe.passthrough: true.
Ubiquiti's table: "Power Method: PoE / PoE+ (Required for PoE output)" and
"Management: (1) PoE in (PoE output not used) / (1) Passive PoE output". No
wattage is printed for the output port; the page's only figures are the included
48V 0.32A adapter (15.4 W into the box) and "Max. Power Consumption: 9W".

ubiquiti/F-POE-G2 (devices/ubiquiti/f-poe-g2.json) - poe.passthrough: true, and
the sourceUrl was broken: it ended "...outdoor-poe-d" and 307s to the techspecs
home page, so the file cited a page with no product on it. Corrected to
.../uisp/fiber/optical-data-transport-for-outdoor-poe-devices (200, 587,458 B),
whose Power Method row uses the vendor's own word: "4-pair (24V DC/50V DC input)
passthrough ... PoE passthrough".

The other two boxes this step named had already left the cohort through their own
sheets: planet/POE-E201 by budgetW: 26 and ubiquiti/UACC-LR-Endpoint by
budgetW: 60, because both vendors print a figure for the outlet.

Audit, before -> after:
  Silent: 2 -> 0
  Passthrough: 0 -> 2  (ubiquiti/UDB-Pro, ubiquiti/F-POE-G2)
  Contradictory passthrough declarations: 0
  node scripts/audit-poe-budget.js --strict: exit 1 -> exit 0 on the real catalogue

The engine is untouched: these ports still serve 0 W, so the flag buys an honest
audit line, not working power. Step 3 (the package.json gate) is now unblocked;
step 5 (docs/DEVICE_SCHEMA.md) is the next thing owed, since two files now set a
field the schema does not define.

Gates: syntax 560 files OK; audit-port-types gated 0; audit-devices gated 0;
hardware-invariants 26/26; poe-budget-gate 18 assertions; importer dry-run
unchanged (its exit 1 on baseline too, from pre-existing research/incoming
warnings); full run 475/476 with canonical-urls' dirty-README flake, green
standalone (86/86); registry doc current (2,352 models, no port change).
forgejo-actions scheduled this pull request to auto merge when all checks succeed 2026-11-24 01:32:34 +00:00
jaylouisw deleted branch catalogue/1124-0122 2026-11-24 01:39:40 +00:00
Sign in to join this conversation.