devices(planet): POE-E201 carries its own 26 W PoE out, not the 802.3at class ceiling #2487

Merged
jaylouisw merged 1 commit from catalogue/1123-2327 into main 2026-11-23 23:32:13 +00:00
Owner

The device-request queue is empty (all 20 [Device]: issues are closed, #130 last), so this run took the next member of the silent PoE cohort the queue left behind.

devices/planet/poe-e201.json shipped poeOut: 30 - the 802.3at PSE class ceiling, which PLANET does not sell this jack at - and no poe block at all, so scripts/audit-poe-budget.js listed it as silent: Device asked the model-name parser for a budget, got 0, Simulator.computePoe() skipped it, and show power inline printed "budget not modelled". A 25.5 W PoE+ access point on poe_out had neither a total nor a ceiling to be judged against.

Sources (both read 2026-11-23)

  • https://www.planet.com.tw/storage/products/49453/C-POE-E201v2_L.pdf - HTTP 200, 951,342 B, 4 pp, text layer, Specifications -> Power over Ethernet: PoE Power Supply Type | "PoE In" Port: IEEE 802.3at PoE+ end-span/mid-span PD class 4 PD | Per "PoE Out" Port: IEEE 802.3at PoE+ end-span PSE; PoE Power | "PoE In" Port: 48~56V DC, max. 30.8 watts | "PoE Out" Port: 44~52V DC, max. 26 watts; Power Consumption: 2.6 watts (system maximum).
  • https://www.planet.com.tw/storage/products/49453/EM-POE-E201_v2.0.pdf - HTTP 200, 1,389,185 B, quick-install guide: PoE Power 44~52V DC, 510mA; max. 26 watts, System Power 2.6 watts (System on).

The change

  • poe_out: 26 W, class PoE+ (was 30 W, the class ceiling)
  • poe_in: 30.8 W, the inlet ceiling, and the row now declares poe-pd as well as poe-pse, so an upstream switch bills the extender instead of treating it as an unpowered two-port box
  • poe.budgetW: 26 - the single PSE socket is the whole of what it can hand on - cited to the sheet above, with the reading recorded in poe.note
  • docs/plans/poe-budget-variants.md: silent cohort 4 -> 3, with the reason (step 2's "vendor publishes a port figure" branch, not passthrough)

The contradiction, recorded not modelled: the product page (https://www.planet.com.tw/en/product/poe-e201-v2, HTTP 200, 103,569 B, read 2026-11-23) prints 2.6 watts (system maximum) /PoE Output at maximum 36 watts. 36 W out of a jack whose printed input maximum is 30.8 W is not physically possible, and 30.8 - 2.6 leaves 28.2 W at the very most; the sheet and the QIG both say 26 W, so 26 W is what the port and the budget carry and the 36 W line stays in poe.note as a vendor error.

Tests test/planet-poe-e201-budget.test.js (27 assertions): the two jack figures, the budget and its citation, poeBudgetSource === 'research', a 25.5 W AP powered and printed (Available:26.0(w) Used:25.5(w) Remaining:0.5(w)), and a 32 W device refused with PSE budget exhausted: 32 W requested, 26 W left.

Gates: syntax-check 549 files OK; audit-port-types 0 gated (2704 reported template ports, unchanged); audit-devices 0 gated; audit-poe-budget silent 3 (was 4), 0 orphan, 0 inferred; run-tests 468 suites / 15,793 assertions with one canonical-urls failure that only occurs mid-run on a dirty tree (--allow-dirty) - green standalone, 58 passed, 0 failed.

The device-request queue is empty (all 20 `[Device]:` issues are closed, #130 last), so this run took the next member of the silent PoE cohort the queue left behind. `devices/planet/poe-e201.json` shipped `poeOut: 30` - the 802.3at PSE class ceiling, which PLANET does not sell this jack at - and no `poe` block at all, so `scripts/audit-poe-budget.js` listed it as silent: `Device` asked the model-name parser for a budget, got 0, `Simulator.computePoe()` skipped it, and `show power inline` printed "budget not modelled". A 25.5 W PoE+ access point on `poe_out` had neither a total nor a ceiling to be judged against. **Sources (both read 2026-11-23)** - `https://www.planet.com.tw/storage/products/49453/C-POE-E201v2_L.pdf` - HTTP 200, 951,342 B, 4 pp, text layer, Specifications -> Power over Ethernet: `PoE Power Supply Type | "PoE In" Port: IEEE 802.3at PoE+ end-span/mid-span PD class 4 PD | Per "PoE Out" Port: IEEE 802.3at PoE+ end-span PSE`; `PoE Power | "PoE In" Port: 48~56V DC, max. 30.8 watts | "PoE Out" Port: 44~52V DC, max. 26 watts`; `Power Consumption: 2.6 watts (system maximum)`. - `https://www.planet.com.tw/storage/products/49453/EM-POE-E201_v2.0.pdf` - HTTP 200, 1,389,185 B, quick-install guide: `PoE Power 44~52V DC, 510mA; max. 26 watts`, `System Power 2.6 watts (System on)`. **The change** - `poe_out`: 26 W, class `PoE+` (was 30 W, the class ceiling) - `poe_in`: 30.8 W, the inlet ceiling, and the row now declares `poe-pd` as well as `poe-pse`, so an upstream switch bills the extender instead of treating it as an unpowered two-port box - `poe.budgetW: 26` - the single PSE socket is the whole of what it can hand on - cited to the sheet above, with the reading recorded in `poe.note` - `docs/plans/poe-budget-variants.md`: silent cohort 4 -> 3, with the reason (step 2's "vendor publishes a port figure" branch, not `passthrough`) **The contradiction, recorded not modelled:** the product page (`https://www.planet.com.tw/en/product/poe-e201-v2`, HTTP 200, 103,569 B, read 2026-11-23) prints `2.6 watts (system maximum) /PoE Output at maximum 36 watts`. 36 W out of a jack whose printed input maximum is 30.8 W is not physically possible, and 30.8 - 2.6 leaves 28.2 W at the very most; the sheet and the QIG both say 26 W, so 26 W is what the port and the budget carry and the 36 W line stays in `poe.note` as a vendor error. **Tests** `test/planet-poe-e201-budget.test.js` (27 assertions): the two jack figures, the budget and its citation, `poeBudgetSource === 'research'`, a 25.5 W AP powered and printed (`Available:26.0(w) Used:25.5(w) Remaining:0.5(w)`), and a 32 W device refused with `PSE budget exhausted: 32 W requested, 26 W left`. **Gates:** syntax-check 549 files OK; audit-port-types 0 gated (2704 reported template ports, unchanged); audit-devices 0 gated; audit-poe-budget silent 3 (was 4), 0 orphan, 0 inferred; run-tests 468 suites / 15,793 assertions with one `canonical-urls` failure that only occurs mid-run on a dirty tree (`--allow-dirty`) - green standalone, 58 passed, 0 failed.
devices(planet): POE-E201 carries its own 26 W PoE out, not the 802.3at class ceiling
All checks were successful
CI / Typecheck (pull_request) Successful in 16s
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 10s
CI / Server smoke and Docker build (pull_request) Successful in 31s
CI / Test (Node 22) (pull_request) Successful in 47s
CI / Test (Node 24) (pull_request) Successful in 47s
CI / Arm auto-merge (pull_request) Successful in 3s
1459a9c8c2
The extender shipped `poeOut: 30` (the class ceiling PLANET does not sell this jack at)
and no `poe` block, so it sat in scripts/audit-poe-budget.js's silent cohort: `show
power inline` printed "budget not modelled" and a 25.5 W PoE+ AP on poe_out had no
ceiling or total to be judged against.

PLANET's catalogue sheet (C-POE-E201v2_L.pdf, 951,342 B, 4 pp, read 2026-11-23):
  PoE Power | "PoE In" Port: 48~56V DC, max. 30.8 watts
            | "PoE Out" Port: 44~52V DC, max. 26 watts
  Power Consumption: 2.6 watts (system maximum)
and the QIG repeats 26 W / 2.6 W. So poe_out is 26 W (PoE+), poe_in is 30.8 W, the row
declares poe-pd as well as poe-pse, and poe.budgetW is 26 - the single PSE socket is the
whole of what it can hand on, which drops the silent cohort from 4 to 3.

The product page's own "PoE Output at maximum 36 watts" cannot be true against a 30.8 W
input maximum, so it is recorded in poe.note as a vendor error and deliberately not
modelled. test/planet-poe-e201-budget.test.js pins the figures, the PD billing on the
inlet, a 25.5 W AP powered at the ceiling, and a 32 W device refused with the arithmetic.

Gates: syntax-check 549 files OK; audit-port-types 0 gated; audit-devices 0 gated;
audit-poe-budget silent 3; run-tests 468 suites, 15793 assertions (canonical-urls flakes
mid-run on a dirty tree, green standalone: 58 passed).
forgejo-actions scheduled this pull request to auto merge when all checks succeed 2026-11-23 23:30:14 +00:00
Sign in to join this conversation.