devices(planet): POE-E201 carries its own 26 W PoE out, not the 802.3at class ceiling #2487
No reviewers
Labels
No labels
blocked-on-build
bug
device
device-request
enhancement
from-github
needs-datasheet
needs-info
needs-triage
ready-for-agent
ready-for-human
wontfix
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!2487
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1123-2327"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
The device-request queue is empty (all 20
[Device]:issues are closed, #130 last), so this run took the next member of the silent PoE cohort the queue left behind.devices/planet/poe-e201.jsonshippedpoeOut: 30- the 802.3at PSE class ceiling, which PLANET does not sell this jack at - and nopoeblock at all, soscripts/audit-poe-budget.jslisted it as silent:Deviceasked the model-name parser for a budget, got 0,Simulator.computePoe()skipped it, andshow power inlineprinted "budget not modelled". A 25.5 W PoE+ access point onpoe_outhad neither a total nor a ceiling to be judged against.Sources (both read 2026-11-23)
https://www.planet.com.tw/storage/products/49453/C-POE-E201v2_L.pdf- HTTP 200, 951,342 B, 4 pp, text layer, Specifications -> Power over Ethernet:PoE Power Supply Type | "PoE In" Port: IEEE 802.3at PoE+ end-span/mid-span PD class 4 PD | Per "PoE Out" Port: IEEE 802.3at PoE+ end-span PSE;PoE Power | "PoE In" Port: 48~56V DC, max. 30.8 watts | "PoE Out" Port: 44~52V DC, max. 26 watts;Power Consumption: 2.6 watts (system maximum).https://www.planet.com.tw/storage/products/49453/EM-POE-E201_v2.0.pdf- HTTP 200, 1,389,185 B, quick-install guide:PoE Power 44~52V DC, 510mA; max. 26 watts,System Power 2.6 watts (System on).The change
poe_out: 26 W, classPoE+(was 30 W, the class ceiling)poe_in: 30.8 W, the inlet ceiling, and the row now declarespoe-pdas well aspoe-pse, so an upstream switch bills the extender instead of treating it as an unpowered two-port boxpoe.budgetW: 26- the single PSE socket is the whole of what it can hand on - cited to the sheet above, with the reading recorded inpoe.notedocs/plans/poe-budget-variants.md: silent cohort 4 -> 3, with the reason (step 2's "vendor publishes a port figure" branch, notpassthrough)The contradiction, recorded not modelled: the product page (
https://www.planet.com.tw/en/product/poe-e201-v2, HTTP 200, 103,569 B, read 2026-11-23) prints2.6 watts (system maximum) /PoE Output at maximum 36 watts. 36 W out of a jack whose printed input maximum is 30.8 W is not physically possible, and 30.8 - 2.6 leaves 28.2 W at the very most; the sheet and the QIG both say 26 W, so 26 W is what the port and the budget carry and the 36 W line stays inpoe.noteas a vendor error.Tests
test/planet-poe-e201-budget.test.js(27 assertions): the two jack figures, the budget and its citation,poeBudgetSource === 'research', a 25.5 W AP powered and printed (Available:26.0(w) Used:25.5(w) Remaining:0.5(w)), and a 32 W device refused withPSE budget exhausted: 32 W requested, 26 W left.Gates: syntax-check 549 files OK; audit-port-types 0 gated (2704 reported template ports, unchanged); audit-devices 0 gated; audit-poe-budget silent 3 (was 4), 0 orphan, 0 inferred; run-tests 468 suites / 15,793 assertions with one
canonical-urlsfailure that only occurs mid-run on a dirty tree (--allow-dirty) - green standalone, 58 passed, 0 failed.The extender shipped `poeOut: 30` (the class ceiling PLANET does not sell this jack at) and no `poe` block, so it sat in scripts/audit-poe-budget.js's silent cohort: `show power inline` printed "budget not modelled" and a 25.5 W PoE+ AP on poe_out had no ceiling or total to be judged against. PLANET's catalogue sheet (C-POE-E201v2_L.pdf, 951,342 B, 4 pp, read 2026-11-23): PoE Power | "PoE In" Port: 48~56V DC, max. 30.8 watts | "PoE Out" Port: 44~52V DC, max. 26 watts Power Consumption: 2.6 watts (system maximum) and the QIG repeats 26 W / 2.6 W. So poe_out is 26 W (PoE+), poe_in is 30.8 W, the row declares poe-pd as well as poe-pse, and poe.budgetW is 26 - the single PSE socket is the whole of what it can hand on, which drops the silent cohort from 4 to 3. The product page's own "PoE Output at maximum 36 watts" cannot be true against a 30.8 W input maximum, so it is recorded in poe.note as a vendor error and deliberately not modelled. test/planet-poe-e201-budget.test.js pins the figures, the PD billing on the inlet, a 25.5 W AP powered at the ceiling, and a 32 W device refused with the arithmetic. Gates: syntax-check 549 files OK; audit-port-types 0 gated; audit-devices 0 gated; audit-poe-budget silent 3; run-tests 468 suites, 15793 assertions (canonical-urls flakes mid-run on a dirty tree, green standalone: 58 passed).