devices(ubiquiti): ten door-access hubs sourced PoE on the port that is powered, and none had a budget #2280
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!2280
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1120-0822"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #130 only (no closing keyword - the UDW-PRO question is untouched; this is queue-stream catalogue work on the same surface, Ubiquiti PoE rows).
Defect.
node scripts/audit-poe-budget.jslisted 25 Ubiquiti specs as "Silent (PoE out, no budget)". Almost all are door access, and on ten of them the direction was also inverted: eth0 declaredpoeOutclassPoE++- the uplink the switch feeds - while the jacks a camera is cabled to declared nothing. So the spec advertised a 60 W source on its input, and the real outputs could source nothing.Vendor row (
https://techspecs.ui.com/unifi/door-access/ua-hub-door, HTTP 200, 624,799 B, read 2026-11-20):Ten files, same shape (
techspecs.ui.com/unifi/door-access/<slug>):eah-8is the same defect in another form: its description said "240 W max", which is Max. Power Consumption; the PSE allocation is 190 W across eight 30 W outputs. Outputs are modelledPoE+because every page gives 30 W per port (802.3at Type 2) even where the row says "PoE outputs"; pages printing10/100/1000 Base-Talso gained the 10M rung on both banks.Lab-visible effect. Dream Wall (PoE++ 420 W) -> UA-Hub-Door eth0, four 12.95 W PDs on eth1-eth4: before, hub budget 0 W (PSE skipped by
computePoe()), nothing powered; after, budget 45 W, three PDs powered (38.85 W) and the fourth refused -PSE budget exhausted: 12.95 W requested, 6.15 W left.Gates.
node scripts/syntax-check.js(485 files OK);node scripts/audit-port-types.js(0 offending ports);node scripts/audit-poe-budget.js(silent PSEs 85 -> 75, Ubiquiti 25 -> 15);node test/hardware-invariants.test.js(26/26);node test/poe.test.js(21/21);node test/spec-vs-description.test.js(3/3);node test/port-roles.test.js(19/19);node test/request-queue.test.js(32/32);npm run regen:registry-doc(no drift).Not touched, and why:
ua-g3-sk-elevatorprints (4) 10/100/1000 Base-T and Management (1) 10/100/1000 Base-T - five jacks - while its PoE row is 1 in + 4 out, also five; the jack map cannot be resolved from the page, so nothing was written rather than guessing.ua-sk-elevator/ua-sk-gatestill need their own pages read.Evidence note:
research/ubiquiti-door-access-hub-poe-direction.md.