Does not close #743 - the IOM census is still unpublished, and no spec is written from research notes.
What this pass found
1. The probe method was under-controlled. The support doc viewer returns the same 3,800-byte SPA shell to a default
curluser-agent for a section that renders and for one that does not:EDOC1100318730/ce945100/cabinet-layout-and-connection-planningEDOC1100318733/4f560405/cabinet-layout-and-connection-planningSo
200 + shellmeans not measured. A404with the/view/notFoundbody does discriminate.2. Under that controlled user-agent, the X8100/X9100 books are absent, not bounced.
EDOC1100368229,EDOC1100368230andEDOC1100305240answer 404 on the bare root, on a slug with no hash, and on a borrowed topic hash - while sibling books render in the same session, minutes apart. Topic hashes are revision-scoped, so there is no enumeration entry point. The section 12 conclusion holds, now controlled for user-agent.3. The frame census no longer needs those books.
https://e.huawei.com/en/products/storage/oceanprotect/x100-seriespublishes 2 controllers (X8100) and 4 (X9100), max 4/8 per system, front-end types16/32/64 Gbit/s FC; 10/25/40/100GE, and node enclosures 86.1 x 447 x 920 mm (2 U) / 175 x 447 x 865 mm (4 U). It publishes no IOM slot count and no per-module port count.4. The vendor names the tool that would finish it. The readable Interface Module chapter says verbatim: "For details about the types of hot-swappable interface modules supported by each product model, see Spare Parts Query", linking
https://info.support.huawei.com/storage/spareparts/#/home. Public page, JavaScript app, needs a browser rather than a fetch. Now the first-listed unblock route, ahead of re-trying the books.Still missing (#743)
IOM slots that accept front-end interface modules on X8100 (2 U, 2 controllers) and X9100 (4 U, 4 controllers), plus the port count of each 10/25/40/100GE and 16/32/64 Gbit/s FC module fitted to those models. A 2 U frame with an unpublished IOM population would be an empty array, not a census, so nothing is modelled from it.
Gates
node scripts/syntax-check.js- 390 files, all OKnode scripts/audit-port-types.js- no port contradicts its declared typenode scripts/check-control-bytes.js- no control bytes in sourcedocs/DEVICE_REGISTRY.mdneeds no regeneration69a0f0ae423f75f6bcbf