No reviewers
Labels
No labels
blocked-on-build
bug
device
device-request
enhancement
from-github
needs-datasheet
needs-info
needs-triage
ready-for-agent
ready-for-human
wontfix
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!1362
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "devices/xgs-pon-ont-batch"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Three ONT entries corrected against the vendor pages, plus one SKU the catalogue was missing.
This started as four new specs. While the batch sat in the CI queue,
mainmoved — nine more ONT PRs merged, includinggenexis/xgs2110-2-5g.json,comtrend/grg-4362.jsonand a singlecig/xg-99c.json— so what is left to do is the partthose entries do not say. Their files are kept; only the corrections below are this PR's.
Corrections
comtrend/GRG-4362gainsl3-forward. The vendor's own spec page states "Routing Function: Routing softwarefunction integrated" and sells the box as an XGS-PON Bridge/Gateway. The entry had
l2-forwardonly, so a labwould have modelled a device the vendor calls a gateway as a pure bridge — it would not route between subnets. Its
notes now also carry the vendor's rows:
XGS-PON x1(PHY US 10Gbps, DS 10Gbps, ITU-T G.987, US 1270 nm, DS 1577 nm),10Giga Ethernet x1(10G/5G/2.5G/1G/100M/10M bps, 802.3an/bz/ab/u/i, Auto-MDIX) and the 12 Vdc/1.0 A adapter.genexis/XGS2110-2.5Ggains notes with the vendor's interface rows (WAN interface 1x XGS-PON,LAN interface 1x 2.5GE) and its power figures (12 Vdc ± 5%, 3.2 W idle and on). The ports were already right; the record of whywas missing.
cig/XG-99Cgains notes naming which configuration it models. Its datasheet's model table splits the product:XG-99C1(10GBase-T only) andXG-99C2(10GE + 1GE, "for legacy device connectivity or service separation"). Theexisting entry models the first.
Addition
cig/XG-99C2— the SKU with the second Ethernet port. Its own entry rather than a note onXG-99C, because onespec cannot describe both: it would either invent a port on the C1 or lose one on the C2, and
XG-99C2would cableinto something the catalogue says it does not have.
The import record was cut down to the single device this batch adds. Leaving the superseded entries in it would have
re-created a file the catalogue already holds on the next
--apply.Counts and gates
Counts regenerated from
loadCatalog()on this merged tree: 2,038 models across 251 vendors. Vendor and categoryrows already agreed; only the headline had drifted.
npm run syntax— 250 files, all OK.npm test— 183 suites, 7,115 assertions, 0 failed.Add four XGS-PON ONTs: Genexis XGS2110-2.5G, Comtrend GRG-4362, CIG XG-99C1 and XG-99C2 (#1349, #1350, #1353)to Correct three ONT entries against the vendor pages, add the CIG XG-99C2 SKU (#1349, #1350, #1353)This branch conflicts with
main, so it was not rebased:A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.
This branch conflicts with
main, so it was not rebased:A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.