Correct three ONT entries against the vendor pages, add the CIG XG-99C2 SKU (#1349, #1350, #1353) #1362

Merged
jaylouisw merged 2 commits from devices/xgs-pon-ont-batch into main 2026-11-10 12:30:19 +00:00
Owner

Three ONT entries corrected against the vendor pages, plus one SKU the catalogue was missing.

This started as four new specs. While the batch sat in the CI queue, main moved — nine more ONT PRs merged, including
genexis/xgs2110-2-5g.json, comtrend/grg-4362.json and a single cig/xg-99c.json — so what is left to do is the part
those entries do not say. Their files are kept; only the corrections below are this PR's.

Corrections

comtrend/GRG-4362 gains l3-forward. The vendor's own spec page states "Routing Function: Routing software
function integrated"
and sells the box as an XGS-PON Bridge/Gateway. The entry had l2-forward only, so a lab
would have modelled a device the vendor calls a gateway as a pure bridge — it would not route between subnets. Its
notes now also carry the vendor's rows: XGS-PON x1 (PHY US 10Gbps, DS 10Gbps, ITU-T G.987, US 1270 nm, DS 1577 nm),
10Giga Ethernet x1 (10G/5G/2.5G/1G/100M/10M bps, 802.3an/bz/ab/u/i, Auto-MDIX) and the 12 Vdc/1.0 A adapter.

genexis/XGS2110-2.5G gains notes with the vendor's interface rows (WAN interface 1x XGS-PON, LAN interface 1x 2.5GE) and its power figures (12 Vdc ± 5%, 3.2 W idle and on). The ports were already right; the record of why
was missing.

cig/XG-99C gains notes naming which configuration it models. Its datasheet's model table splits the product:
XG-99C1 (10GBase-T only) and XG-99C2 (10GE + 1GE, "for legacy device connectivity or service separation"). The
existing entry models the first.

Addition

cig/XG-99C2 — the SKU with the second Ethernet port. Its own entry rather than a note on XG-99C, because one
spec cannot describe both: it would either invent a port on the C1 or lose one on the C2, and XG-99C2 would cable
into something the catalogue says it does not have.

The import record was cut down to the single device this batch adds. Leaving the superseded entries in it would have
re-created a file the catalogue already holds on the next --apply.

Counts and gates

Counts regenerated from loadCatalog() on this merged tree: 2,038 models across 251 vendors. Vendor and category
rows already agreed; only the headline had drifted.

npm run syntax — 250 files, all OK. npm test — 183 suites, 7,115 assertions, 0 failed.

Three ONT entries corrected against the vendor pages, plus one SKU the catalogue was missing. This started as four new specs. While the batch sat in the CI queue, `main` moved — nine more ONT PRs merged, including `genexis/xgs2110-2-5g.json`, `comtrend/grg-4362.json` and a single `cig/xg-99c.json` — so what is left to do is the part those entries do not say. Their files are kept; only the corrections below are this PR's. ## Corrections **`comtrend/GRG-4362` gains `l3-forward`.** The vendor's own spec page states *"Routing Function: Routing software function integrated"* and sells the box as an **XGS-PON Bridge/Gateway**. The entry had `l2-forward` only, so a lab would have modelled a device the vendor calls a gateway as a pure bridge — it would not route between subnets. Its notes now also carry the vendor's rows: `XGS-PON x1` (PHY US 10Gbps, DS 10Gbps, ITU-T G.987, US 1270 nm, DS 1577 nm), `10Giga Ethernet x1` (10G/5G/2.5G/1G/100M/10M bps, 802.3an/bz/ab/u/i, Auto-MDIX) and the 12 Vdc/1.0 A adapter. **`genexis/XGS2110-2.5G` gains notes** with the vendor's interface rows (`WAN interface 1x XGS-PON`, `LAN interface 1x 2.5GE`) and its power figures (12 Vdc ± 5%, 3.2 W idle and on). The ports were already right; the record of *why* was missing. **`cig/XG-99C` gains notes naming which configuration it models.** Its datasheet's model table splits the product: `XG-99C1` (10GBase-T only) and `XG-99C2` (10GE + 1GE, *"for legacy device connectivity or service separation"*). The existing entry models the first. ## Addition **`cig/XG-99C2`** — the SKU with the second Ethernet port. Its own entry rather than a note on `XG-99C`, because one spec cannot describe both: it would either invent a port on the C1 or lose one on the C2, and `XG-99C2` would cable into something the catalogue says it does not have. The import record was cut down to the single device this batch adds. Leaving the superseded entries in it would have re-created a file the catalogue already holds on the next `--apply`. ## Counts and gates Counts regenerated from `loadCatalog()` on this merged tree: **2,038 models across 251 vendors**. Vendor and category rows already agreed; only the headline had drifted. `npm run syntax` — 250 files, all OK. `npm test` — **183 suites, 7,115 assertions, 0 failed**.
Add four XGS-PON ONTs: Genexis XGS2110-2.5G, Comtrend GRG-4362, CIG XG-99C1 and XG-99C2 (#1349, #1350, #1353)
Some checks failed
CI / Classify the change (pull_request) Successful in 11s
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 10s
CI / Test (Node 18) (pull_request) Successful in 2m34s
CI / Test (Node 20) (pull_request) Successful in 2m24s
CI / Server smoke test (pull_request) Has been skipped
CI / Docker build (pull_request) Has been skipped
CI / Test (Node 22) (pull_request) Failing after 2m23s
57b90ceb58
Four specs, each written from the vendor's own specification rows:

- Genexis FiberTwist XGS2110-2.5G: 'WAN interface 1x XGS-PON', 'LAN interface 1x 2.5GE', 12 Vdc, 3.2 W.
- Comtrend GRG-4362: 'XGS-PON x1' (ITU-T G.987, US 1270 nm / DS 1577 nm) and '10Giga Ethernet x1'
  (10G/5G/2.5G/1G/100M/10M, auto-MDIX); integrated routing function, TR-069, 12 Vdc/1 A adapter.
- CIG XG-99C1: 1x 10GBase-T LAN, SC/APC optical, Class N1, under 10 W from a 12 V DC adapter.
- CIG XG-99C2: the same box plus a 10/100/1000Base-T port. Its own entry, because the port count
  differs and one spec cannot describe both SKUs.

The generator of the counts page was stale before this batch (the ONT work merged since #1358 moved
five rows), so the page was rewritten from loadCatalog() in this tree: 2,028 models across 248
vendors, point-to-point 212, Huawei 82. test/doc-catalog-counts.test.js passes 19 of 19.

Suite: 183 suites, 7,115 assertions, 0 failed.
Correct three ONT entries against the vendor pages, add the CIG XG-99C2 SKU (#1349, #1353, #1350)
Some checks failed
CI / Classify the change (pull_request) Successful in 11s
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 11s
CI / Test (Node 18) (pull_request) Failing after 2m31s
CI / Test (Node 20) (pull_request) Successful in 2m23s
CI / Server smoke test (pull_request) Has been skipped
CI / Docker build (pull_request) Has been skipped
CI / Test (Node 22) (pull_request) Successful in 2m30s
e3fa12e47f
While this batch was waiting on the runner, main moved: nine more ONT PRs merged, including
Genexis XGS2110-2.5G, Comtrend GRG-4362 and a single CIG XG-99C. So the batch is now corrections
and one addition rather than four new files.

Corrected, each against the vendor's own page:

- comtrend/GRG-4362 gains l3-forward. The vendor states 'Routing function: Routing software function
  integrated' and sells the box as a Bridge/Gateway; the entry had no routing capability, so a lab
  would have treated a device the vendor calls a gateway as a pure bridge. Its notes now carry the
  vendor's port rows (ITU-T G.987, US 1270 nm / DS 1577 nm, 10G/5G/2.5G/1G/100M/10M, Auto-MDIX) and
  the 12 Vdc/1 A adapter.
- genexis/XGS2110-2.5G gains notes: the vendor interface rows, 12 Vdc +/- 5%, 3.2 W idle and on.
- cig/XG-99C gains notes naming which configuration it is. The datasheet's model table lists
  XG-99C1 (10GBase-T only) and XG-99C2 (10GE + 1GE); the existing entry models the first.

Added: cig/XG-99C2, the SKU with the second Ethernet port. Its own entry, because one spec cannot
describe both - it would either invent a port on the C1 or lose one on the C2.

The import record was cut down to the one device this batch adds; leaving the superseded entries in
it would have re-created a file the catalogue already holds on the next --apply.

Counts page regenerated from loadCatalog() on this tree: 2,038 models across 251 vendors.

Suite: 183 suites, 7,115 assertions, 0 failed. Syntax: 250 files, all OK.
jaylouisw changed title from Add four XGS-PON ONTs: Genexis XGS2110-2.5G, Comtrend GRG-4362, CIG XG-99C1 and XG-99C2 (#1349, #1350, #1353) to Correct three ONT entries against the vendor pages, add the CIG XG-99C2 SKU (#1349, #1350, #1353) 2026-11-10 12:22:59 +00:00
Author
Owner

This branch conflicts with main, so it was not rebased:

devices/cig/xg-99c1.json devices/cig/xg-99c2.json devices/comtrend/grg-4362.json devices/genexis/xgs2110-2-5g.json docs/DEVICE_REGISTRY.md research/incoming/devices-xgspon-ont-batch-2.json 

A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.

This branch conflicts with `main`, so it was not rebased: ``` devices/cig/xg-99c1.json devices/cig/xg-99c2.json devices/comtrend/grg-4362.json devices/genexis/xgs2110-2-5g.json docs/DEVICE_REGISTRY.md research/incoming/devices-xgspon-ont-batch-2.json ``` A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.
jaylouisw scheduled this pull request to auto merge when all checks succeed 2026-11-10 12:30:10 +00:00
Author
Owner

This branch conflicts with main, so it was not rebased:

devices/cig/xg-99c.json devices/cig/xg-99c2.json devices/comtrend/grg-4362.json devices/genexis/xgs2110-2-5g.json docs/DEVICE_REGISTRY.md research/incoming/devices-xgspon-ont-batch-2.json 

A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.

This branch conflicts with `main`, so it was not rebased: ``` devices/cig/xg-99c.json devices/cig/xg-99c2.json devices/comtrend/grg-4362.json devices/genexis/xgs2110-2-5g.json docs/DEVICE_REGISTRY.md research/incoming/devices-xgspon-ont-batch-2.json ``` A conflict is a decision about behaviour rather than a mechanical fix, so this is left for a human. Rebasing by hand and force-pushing will let the automation pick it up again.
Sign in to join this conversation.
No description provided.