[Device]: OptiXtrans E6608T #804

Closed
opened 2026-11-08 06:21:15 +00:00 by jaylouisw · 2 comments
Owner

Vendor

Huawei

Exact model name

OptiXtrans E6608T

Category

Other / not sure

Ports and interfaces

  • 7 (DC) / 5 (AC) service board slots
  • 2U (88.1mm) x 442mm x 220mm
  • 100 Gbit/s grey per channel; 96 DWDM channels

PoE budget (watts)

None (no PoE output)

Datasheet or product page URL

https://e.huawei.com/en/products/optical-transmission/optixtrans-e6600

What do you want to model with it?

Compact metro access MS-OTN node (T variant).

Capabilities

MS-OTN; OTN/PKT/SDH unified switching

Before submitting

  • I searched the catalog and existing issues, and this model is not there yet.
  • The port list above comes from a datasheet, not from memory or another wiki.
### Vendor Huawei ### Exact model name OptiXtrans E6608T ### Category Other / not sure ### Ports and interfaces - 7 (DC) / 5 (AC) service board slots - 2U (88.1mm) x 442mm x 220mm - 100 Gbit/s grey per channel; 96 DWDM channels ### PoE budget (watts) None (no PoE output) ### Datasheet or product page URL https://e.huawei.com/en/products/optical-transmission/optixtrans-e6600 ### What do you want to model with it? Compact metro access MS-OTN node (T variant). ### Capabilities MS-OTN; OTN/PKT/SDH unified switching ### Before submitting - [x] I searched the catalog and existing issues, and this model is not there yet. - [x] The port list above comes from a datasheet, not from memory or another wiki.
Author
Owner

Closing status: blocked on a stated configuration.

The OptiXtrans E6600/E9600 specification tables publish what a frame can do - service board slots (E6600: "Number of Service Board Slots: DC chassis 14 / AC chassis 12"), cross-connect capacity, maximum wavelengths and per-channel rate - and nothing about ports, because an OTN subrack has none until service boards are fitted. A 400G/λ, 96-wavelength figure is a capacity, not a socket count.

So the issue stays open; docs/DEVICE_REGISTRY.md §"What is left open, and why" records the reason for the family (#803, #804, #807, #808, #810).

What would close it: the board set you intend to model (e.g. "E6616 with two TN13LSC boards"), or a decision to model the frame's slots as a repeatable module - which would be an engine feature, not a spec file.

Closing status: **blocked on a stated configuration.** The OptiXtrans E6600/E9600 specification tables publish what a *frame* can do - service board slots (E6600: "Number of Service Board Slots: DC chassis 14 / AC chassis 12"), cross-connect capacity, maximum wavelengths and per-channel rate - and nothing about ports, because an OTN subrack has none until service boards are fitted. A 400G/λ, 96-wavelength figure is a capacity, not a socket count. So the issue stays open; `docs/DEVICE_REGISTRY.md` §"What is left open, and why" records the reason for the family (#803, #804, #807, #808, #810). **What would close it:** the board set you intend to model (e.g. "E6616 with two TN13LSC boards"), or a decision to model the frame's slots as a repeatable module - which would be an engine feature, not a spec file.
Author
Owner

Still blocked, and the E6600 generation has now been read against its own documents. One correction to this request first: this is not an MS-OTN node.

The E6608T is a photonic shelf. The E6600 spec table (https://e.huawei.com/en/products/optical-transmission/optixtrans-e6600, HTTP 200, 339,757 B) gives the T its own column: Number of Service Board Slots | DC chassis: 7, AC chassis: 5 (E6608: 6/4, in the same 2 U 4.9 kg enclosure), Cross-connect Capacity | NA, Maximum Number of Wavelengths | DWDM 96, CWDM 8, Maximum Rate per Channel | 400 Gbit/s. There is no OTN, packet or SDH cross-connect behind those slots — the same shape as the E9605 in the E9600 family, one generation over. So the capability line above ("MS-OTN; OTN/PKT/SDH unified switching") describes the E6608, and "100 Gbit/s grey per channel" is the E6616X row (the EN table's merged cells misplace it; the FR table and the E6616X brochure both put 400 G on E6616/E6608/E6608T). Full reading: research/optixtrans-e6600-xt-census.md.

What is still missing, checked this pass:

  • E6600 product page — slot counts only; the word "board" occurs once, inside "Number of Service Board Slots"; no part number and no port count anywhere.
  • https://e-file.huawei.com/marketingcloud/pep/asset/20000001/Material/621bfc22e8564cf69ae86581569a7594/M3T1A669N1304588489052958777/_2_-OptiXtrans%20E6616-Datasheet.pdf — 200, 1,535,511 B, 29,975 chars of text: chassis, slot layout, capacity, heat. Zero LDCD / B1L strings in the whole text layer.
  • https://e.huawei.com/marketingcloud/pep/asset/20000001/Material/09b99122e93d41d6b062b43ee09f67f7/M3T1A590N1213159367844884537/OptiXtrans%20E6608%20V100R025C10%20Product%20Brochure%20%20_26H1_.docx — 200, 405,011 B docx, 6,771 chars: the E6608 spec table only; the only board codes are K2UXCL / K2UXCLE in the SDH row.
  • The board chapter that pairs boards to subracks, EDOC1100156575BEJ09044, sits on the hedex tree: 302 (Googlebot UA, 0 B), 302 (curl, 0 B), 403 (Chrome UA, 519 B). Closed — unlike the /enterprise/en/doc/ pages, which a crawler UA reads whole.
  • https://www.actfornet.com/solutions/solution/OptiXtrans_E66000_Boards_Overview is titled "E6608T E6608 E6616 Boards Overview" and lists ~40 boards (TMB1LDCD = 4 x 100 Gbit/s to 2 x OTUC2, TMB1LTX 12 x multi-rate, TMK1EX10 10 x 10GE, …) — but it is a partner mirror, so a lead only, and it prints neither a per-subrack validity matrix nor front-panel counts.

Exact missing field: the service-board part number valid in the E6608T subrack, which of the 7 DC / 5 AC service slots accept it, and that board's front-panel port census.

What would close it: one configuration line in the shape already used for E6608/E6616 — "E6608T DC chassis with 7 x TMB1LDCD" = 28 x 100GE client + 14 x 200G line — or the boards-overview page above, or a Huawei ordering guide pinning boards per base model. PR #1794 records the evidence and the reading of the spec table; it does not close this issue.

**Still blocked, and the E6600 generation has now been read against its own documents. One correction to this request first: this is not an MS-OTN node.** **The E6608T is a photonic shelf.** The E6600 spec table (`https://e.huawei.com/en/products/optical-transmission/optixtrans-e6600`, HTTP 200, 339,757 B) gives the T its own column: `Number of Service Board Slots | DC chassis: 7, AC chassis: 5` (E6608: 6/4, in the same 2 U 4.9 kg enclosure), `Cross-connect Capacity | NA`, `Maximum Number of Wavelengths | DWDM 96, CWDM 8`, `Maximum Rate per Channel | 400 Gbit/s`. There is no OTN, packet or SDH cross-connect behind those slots — the same shape as the E9605 in the E9600 family, one generation over. So the capability line above ("MS-OTN; OTN/PKT/SDH unified switching") describes the **E6608**, and "100 Gbit/s grey per channel" is the **E6616X** row (the EN table's merged cells misplace it; the FR table and the E6616X brochure both put 400 G on E6616/E6608/E6608T). Full reading: `research/optixtrans-e6600-xt-census.md`. What is still missing, checked this pass: - E6600 product page — slot counts only; the word "board" occurs once, inside "Number of Service Board Slots"; no part number and no port count anywhere. - `https://e-file.huawei.com/marketingcloud/pep/asset/20000001/Material/621bfc22e8564cf69ae86581569a7594/M3T1A669N1304588489052958777/_2_-OptiXtrans%20E6616-Datasheet.pdf` — 200, 1,535,511 B, 29,975 chars of text: chassis, slot layout, capacity, heat. Zero `LDCD` / `B1L` strings in the whole text layer. - `https://e.huawei.com/marketingcloud/pep/asset/20000001/Material/09b99122e93d41d6b062b43ee09f67f7/M3T1A590N1213159367844884537/OptiXtrans%20E6608%20V100R025C10%20Product%20Brochure%20%20_26H1_.docx` — 200, 405,011 B docx, 6,771 chars: the E6608 spec table only; the only board codes are `K2UXCL` / `K2UXCLE` in the SDH row. - The board chapter that pairs boards to subracks, `EDOC1100156575BEJ09044`, sits on the hedex tree: 302 (Googlebot UA, 0 B), 302 (curl, 0 B), 403 (Chrome UA, 519 B). Closed — unlike the `/enterprise/en/doc/` pages, which a crawler UA reads whole. - `https://www.actfornet.com/solutions/solution/OptiXtrans_E66000_Boards_Overview` is titled "E6608T E6608 E6616 Boards Overview" and lists ~40 boards (`TMB1LDCD` = 4 x 100 Gbit/s to 2 x OTUC2, `TMB1LTX` 12 x multi-rate, `TMK1EX10` 10 x 10GE, …) — but it is a partner mirror, so a lead only, and it prints neither a per-subrack validity matrix nor front-panel counts. **Exact missing field:** the service-board part number valid in the E6608T subrack, which of the 7 DC / 5 AC service slots accept it, and that board's front-panel port census. **What would close it:** one configuration line in the shape already used for E6608/E6616 — "E6608T DC chassis with 7 x TMB1LDCD" = 28 x 100GE client + 14 x 200G line — or the boards-overview page above, or a Huawei ordering guide pinning boards per base model. PR #1794 records the evidence and the reading of the spec table; it does not close this issue.
Sign in to join this conversation.
No milestone
No project
No assignees
1 participant
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".

No due date set.

Dependencies

No dependencies set.

Reference
jaylouisw/packetforge#804
No description provided.