[Device]: NetEngine 8000 M6 #796
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge#796
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Vendor
Huawei
Exact model name
NetEngine 8000 M6
Category
Router
Ports and interfaces
PoE budget (watts)
None (no PoE output)
Datasheet or product page URL
https://e.huawei.com/en/products/routers/ne8000
What do you want to model with it?
Enterprise WAN access/aggregation node.
Capabilities
l3-forward, cli, mpls, bgp, nat, firewall
Before submitting
Closing status: blocked on a stated configuration, and now recorded as such in the repository.
Huawei's NetEngine 8000 page (
https://e.huawei.com/en/products/routers/ne8000.html) publishes, for every model in the family, switching capacity, forwarding performance, capacity density and typical power - but not a port census. The fixed-configuration members say so explicitly ("Fixed-configuration router does not support flexible cards"), and even for those the port list is not on the page; the chassis members publish slots and per-slot capacity ("19.2 Tbit/s per slot ... 42 x 400 GE or 72 x 100 GE") rather than ports that exist in an unconfigured frame.Modelling the maximum would let a lab cable 72 x 100 GE into a chassis with one card; picking a representative card set would be inventing an order. So the issue stays open, and
docs/DEVICE_REGISTRY.md§"What is left open, and why" records why for the whole family (#789, #790, #795, #796, #797, #799, #800, #801, #802).What would close it: one line naming the configuration - "NetEngine 8000 X8 with two 36x100GE boards and one 8x100GE" - and the ports follow directly from Huawei's per-board tables.
Re-checked against the M6's own primary documents; still blocked, but the blocker is now a vendor statement rather than an inference. PR #1777 records it and does not close this issue.
Sources read on 2026-11-17:
What the M6 is. Table 1-29, "Slots on the NetEngine 8000 M6": PIC DC 1-6 / AC 2, 4-6; CXP 7, 8; PIU DC 9, 10 / AC 1, 3; FAN 11. There is no fixed-interface row. Tables 1-30/1-31: DC chassis 11 slots, 6 service board slots; AC 9 slots, 4 service board slots; and a maximum-port block - "Maximum number of physical ports on the entire device: 100", 25GE 6, 10GE 16, 50GE 2, 100GE NA, 40GE NA - which is a maximum over six fitted cards, not a panel. An AC M6 has four service slots and cannot reach those numbers at all.
Why it stays open. The datasheet's basic-configuration BOMs settle it:
CR8PM6BASDC1/CR8PM6BASAC1/CR8PM6BASDC3/CR8PM6BASAC3are "NetEngine 8000 M6 Chassis, 2CXP-160(-B), 2DC/AC Power, without Software Charge and Document" - no PIC. Every interface card is a separate BOM line. So an M6 as ordered has no cableable port; modelling the bare model would mean an entry with no ports, and modelling a representative card set would be inventing an order.Exact missing field: which PICs are fitted, and in which slots - and therefore the port census itself.
What would close it: one line in Huawei part numbers, e.g. "NetEngine 8000 M6 (DC), slots 1-2 = CR8D00L4XFC0 (4x 10GE/GE), slots 3-4 = CR8D00EAGFC0 (10x GE SFP)". For convenience the hardware description already quotes two of its own reference configurations for power measurement - 2CR8D00L4XFC0 + 2CR8D00EAGFC0 = 196.1 W, and 2CR8D00E1VBC0 + 1CR8D00L4XFC0 + 1*CR8D00EAGFC0 = 205.8 W - which are the most likely lab builds (8x 10GE + 20x GE, or 2x 50GE + 4x 10GE + 10x GE). Naming one of those, or your own, converts this to a spec in one step.
The structural fix is unchanged from #797: the catalogue expresses a flat port list, so "6 PIC slots, card-dependent" has no honest representation. A slot list plus a card list would end this class of blocker for #789, #796, #797, #799, #800, #801 and #802 at once.
Closing status: modelled, PR #1911.
devices/huawei/netengine-8000-m6.json- 16 ports, and the build is the vendor's own.This thread's last verdict was right that the DC typical configurations leave slots empty, but it was measured against the DC chassis (11 slots / 6 service slots). The row that settles the M6 is the AC pair in Table 1-31 of
EDOC1100382052:Four PICs against the AC chassis' 4 service slots (9 slots in all) - it fills the chassis exactly, which is the criterion that made the M8 row usable in #1802. Card counts from the vendor Hardware Guide
EDOC1100264779(Issue 05, 2023-03-31), each card's own chapter:CR8D00E1VBC01x50GE QSFP28 (3.4.5.42),CR8D00L4XFC04x10GE/GE SFP+ (3.4.5.52),CR8D00EAGFC010x GE/FE SFP (3.4.5.56) => 2x 50GE + 4x 10GE + 10x GE.Not asserted: card-to-slot assignment (flat port names), ETH management port count, and the other PICs the M6 can take. Full trail in
research/huawei-netengine-8000-m-series-slots.md.