The symptom
Serial WAN links landed yesterday with a rule enforced at cabling time: exactly one end of a V.35 pair supplies the clock, and a link with none — or with two — is refused. Save that lab and reopen it:
The cable now refuses a link that was working when the file was written.
And the port block was lying about the same line, twice:
0Mb/sfor a link that answers a ping is worse than no number: a reader concludes the line is dead. And nothing anywhere said which end clocks it, so the only fact that makes a serial link work was the one fact no surface showed.show running-confighad noclock rateline either — a command that took effect and left no trace.Measured
formatSpeedMbps()rounded to whole megabits:1.544 → 2M,0.064 → 0M,0.1152 → 0M,0.0096 → 0M.serialize()writes 26 keys per port;clockRateBpswas not among them, andDevice.hydrate()had no branch to read it back.show running-configprintedspeedandduplexfor a forced port and nothing for a clocked one.This is the fifth time the save path has dropped a per-port fact —
spec(#1459), DHCP leases (#1465), LLDP neighbours (#1467),speedMbps/maxRangeM(#1405, #1321) — and the shape is identical every time: a fact added to the live object, the serializer left alone, and no test that round-trips that field.What changed
if (i.clockRateBps) doc.clockRateBps = i.clockRateBps;— written only when set, the same rulespeedMbps/natRole/maxRangeMfollow, so an ordinary board does not grow aclockRateBps: nullline on every port in a 2,039-model catalogue.Device.hydrate()restores it, refusing a document that says"fast",-64000, and rounding64000.7the way the command does.clock rate 64000in the interface block, typed-only like everything else in running-config — so a backup of a WAN lab restores a clocked link rather than an invalid one.speed: 1.544Mb/s (auto), link runs at 64Kb/s, DCE, clock rate 64000, duplex: full.64K,115.2K,9.6K— and fractions are kept above it (1.544M,2.5G). Fixing the formatter fixes it everywhere it is used:speedrefusals, the validator's messages, and every port block.Evidence
test/serial-clock-survives-save.test.js— 32 checks, 32 passed / 0 failed; with the fix stashed, 14 failed, printing the old strings (speed: 2Mb/s (auto), link runs at 0Mb/s,1.544 -> 2M (wanted 1.544M)).It asserts the document carries the clock on the clocked port and no key at all on the DTE port or an ethernet port; a reopened lab keeps the clock, the 64 kbps line rate, a clean validation and a working ping; a document with the field stripped is exactly as invalid as the bug made it (
E_SERIAL_NO_CLOCK);no clock rateclears both config and document;show interfacesprints the rated speed, the line rate,DCE, clock rate 64000on the DCE only, and never0Mb/s; ten rates across five units; three hand-edited-document cases; and the document is byte-identical after one, two and three load/save cycles.Docs:
docs/PHYSICAL_LAYER.md§2.1 gains a table of the three places the clock now lives and the before/after of each;docs/ARCHITECTURE.mdgains "The fifth field the save path dropped, and the rate that said zero".Merging the two feature PRs yesterday also moved four citations out of tolerance (
_help(),openFlow(),_deliver()+ a duplicate) — they now point at the definitions themselves, andcheck:citationsis back to its single documented false positive.Full suite: 242 suites, 9,019 assertions, 0 failed. Syntax 311 files.
Serial links landed with a rule enforced at cabling time: exactly one end of a V.35 pair supplies the clock, and a link with none or with two is refused. The clock itself lived on the interface object and nowhere else. * serialize() wrote 26 keys per port and clockRateBps was not one of them, so a saved serial lab reopened unclocked: its own cable then failed validation with E_SERIAL_NO_CLOCK and traffic stopped. The fifth time the save path has dropped a per-port fact (#1405, #1321, #1459, #1465, #1467) with the same shape every time - a fact added to the live object, the serializer left alone, and no test that round-trips that field; * show running-config printed speed and duplex for a forced port and nothing for a clocked one, so a backup of a WAN lab did not say which end is the DCE; * show interfaces printed "speed: 2Mb/s (auto), link runs at 0Mb/s" for a 1.544 Mbps port on a 64 kbps line. formatSpeedMbps() rounded to whole megabits: 1.544 -> 2M, 0.064 -> 0M, 0.1152 -> 0M, 0.0096 -> 0M. Zero for a link that answers a ping is worse than no number. * engine/device.js: clockRateBps is written only when set, by the same rule as speedMbps/natRole/maxRangeM, and hydrate() restores it while refusing "fast", -64000 and rounding 64000.7 the way the command rounds it; * engine/cli.js: "clock rate 64000" in the interface block (typed-only, like the rest of running-config) and "DCE, clock rate 64000" in the port block; * engine/media.js: rates under a megabit are spoken in kilobits (64K, 115.2K, 9.6K) and fractions are kept above it (1.544M, 2.5G) - one formatter, so the speed refusals and the validator's messages stop lying too. test/serial-clock-survives-save.test.js: 32 checks, 32/0; with the fix stashed 14 fail and print the old strings. Covers the key present on the clocked port and absent on the DTE and on ethernet ports, a reopened lab keeping its clock, line rate, clean validation and working ping, a stripped document reproducing E_SERIAL_NO_CLOCK, no clock rate clearing both surfaces, the printout character for character including DCE on one end only and never 0Mb/s, ten rates across five units, three hand-edited documents, and byte-identical documents across three load/save cycles. Merging the two feature PRs also moved four citations out of tolerance; they now point at _help(), openFlow() and _deliver() themselves. Suite 242 suites, 9019 assertions, 0 failed. Syntax 311 files.