devices(mikrotik): nine PoE switches, seven wrong port ranges and five published budgets #2294
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!2294
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1120-1752"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #803, #130 (both still blocked; see the notes at the end).
MikroTik's product pages publish the PoE census port by port (
PoE-out ports,Number of 1G Ethernet ports with PoE-out,Total output power), and the catalogue disagreed with them. The engine infers "every RJ45 port of apoe-pseswitch sources 15.4 W" (isPoePse(),engine/media.js), which is exactly wrong on a reverse-PoE box: it is powered from its subscribers.Wrong ports marked as sources
css610-1gi-7r-2s-out(netPower Lite 7R)PoE-out ports Ether8, 7 x Reverse PoE incrs318-1fi-15fr-2s-out(netPower 15FR)PoE-out ports Ether15, 15 reverse PoErb260gspPoE-out ports Ether2-Ether5(Ether1 = 11-30 V in)gperx6PoE-out ports Ether2-Ether3, Ether1 = 802.3bt incrs320-8p-8b-4s-rmEther1-Ether8 (af/at), Ether9-Ether16 (bt), 17 GbEcrs418-8p-8g-2s-rmPoE-out ports Ether9-Ether16crs354-48p-4s-2q-rmPoE-out ports Ether1-Ether48+ separate10/100 Ethernet ports 1Missing copper ports
crs328-24p-4s-rmbuilds its 24 copper ports from aportTemplatethat carried nopoeOut, so a 24-port PoE switch modelled as unpowered. The template now sources and the spec gainspoe-pse/802.3af/802.3at.Published budgets (
Total output power)css610-8p-2s-in— 140 Wcrs320-8p-8b-4s-rm— 963 W (17.82 A)crs418-8p-8g-2s-rm— 150 W (5.4 A)crs354-48p-4s-2q-rm— 700 W (27 A @26 V / 13.2 A @53 V)gperx6— 150 W, pass-through, and802.3atin the capability list corrected to802.3bt(the input standard; the output is fixed-voltage passive, so the twoPoE+classes becamepassive)Arithmetic not done
NetPower Lite 7R, netPower 15FR, RB260GSP, CRS328 and CRS112-8P-4S-IN state current limits only (
Max total outin A against a voltage window) and never watts. Multiplying 0.6 A by 57 V is arithmetic MikroTik did not do, so those four carrypoe.budgetUnknown: truewith the quoted limit inpoe.noteinstead of a made-up figure.Evidence
All pages read 2026-11-20, HTTP 200,
Mozilla/5.0 … Chrome/126UA:/product/<slug>is case-sensitive, uses underscores, and 404s (13,238 B) on the hyphenised guesses for every one of these;https://mikrotik.com/sitemap.xml(200, 48,450 B, 653 product URLs) is the only reliable way to find the slug.research/mikrotik-poe-out-census.mdrecords the rows verbatim.Gates
node scripts/syntax-check.js— 490 files, all OKnode scripts/audit-port-types.js— no port contradicts its declared typenode scripts/audit-poe-budget.js— silent 69 → 61, unknown-on-purpose 17 → 21, orphan 0node test/hardware-invariants.test.js26/26,spec-vs-description3/3,poe-inference19/19,catalogue-hygiene25/25,faceplate14/14node scripts/run-tests.js— 410 suites, 13,604 assertions, 0 faileddocs/DEVICE_REGISTRY.mdregenerated (no count or shape change: 2,355 models / 258 vendors / 29,735 sockets / 974 shapes)Queue status (unchanged)
#803 (OptiXtrans E6616X) stays blocked on any service-board part number valid in the X subrack, with its front-panel census. #130 (UDW-PRO) stays blocked: no Ubiquiti-published artefact names
UDW-PRO. Neither was re-probed this run; this PR does not close either.MikroTik's product pages publish the PoE census port by port, and the catalogue disagreed with them. The engine infers "every RJ45 port of a `poe-pse` switch sources 15.4 W" (isPoePse()), which is exactly wrong on a reverse-PoE box. Wrong port ranges, from the vendor's `PoE-out ports` row: netPower Lite 7R Ether8 only (was 8 PSE; 7 ports are PoE-*in*) netPower 15FR Ether15 only (was 16 PSE; 15 ports are PoE-*in*) RB260GSP Ether2-Ether5 (was 5; Ether1 is the 11-30 V input) GPERx6 Ether2-Ether3 (was Ether1-Ether2; Ether1 is 802.3bt in) CRS320-8P-8B-4S+RM Ether1-Ether16 (eth17 is the management port) CRS418-8P-8G-2S+RM Ether9-Ether16 (the 8P names the PoE ports, not the first 8) CRS354-48P-4S+2Q+RM Ether1-Ether48 (the 100M management port is not a PSE) Published watts, `Total output power`: CSS610-8P-2S+IN 140, CRS320 963, CRS418 150, CRS354 700, GPERx6 150. CRS328-24P-4S+RM: its 24 copper ports come from a port template that carried no `poeOut`, so a 24-port PoE switch modelled as unpowered. Template now sources, capabilities gain poe-pse/802.3af/802.3at. NetPower Lite 7R, netPower 15FR, RB260GSP, CRS328 and CRS112 publish current limits only (A against a voltage window), never watts - they are marked `poe.budgetUnknown` with the quoted limit in the note rather than multiplied out. Sources: mikrotik.com/product/{css610_8p_2s_in,crs320_8p_8b_4s_rm, crs418_8p_8g_2s_rm,crs354_48p_4s_2q_rm,gperx6,netpower_lite_7r, crs318_1fi_15fr_2s_out,rb260gsp,crs328_24p_4s_rm}, read 2026-11-20. research/mikrotik-poe-out-census.md records the rows and the slug trap (/product/<slug> is case-sensitive, underscores, and 404s on hyphen guesses). Gates: syntax-check 490 files OK; audit-port-types no contradiction; audit-poe-budget silent 69 -> 61, unknown 17 -> 21; run-tests 410 suites, 13,604 assertions, 0 failed.