devices(teltonika): the RUT951 PoE+ had no PoE budget and a Cat 6 link on a Cat 4 radio #2238
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!2238
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1120-0122"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #130 only - this PR does not answer the UDW-PRO request, which stays open on the blocker recorded there. It repairs the cellular-router path that request's lab needs.
What was wrong.
devices/teltonika/rut951-poe.json- the RUT951 PoE+, a cellular router with NAT/DHCP/VPN - declared three PSE ports (wan1,lan2,lan3, eachpoeOut: true, classPoE+) and nopoe.budgetW. The loader therefore fell back to the model name, found no wattage inRUT951-POE+, and set the budget to 0 W withpoeBudgetSource: 'name'.computePoe()skips a device whose budget is falsy, so the box reported:An AP cabled to
lan2got nothing, on a router whose own datasheet prints a 90 W budget - the same defect class as #2235 (USW-Pro-XG-48-PoE) and #2175 (UXG-Fiber).Vendor rows (RUT951 PoE+ datasheet v1.06, 2026-02-10, 15 pp, text layer):
Port 2 - 4 (LAN2, LAN3, WAN)IEEE 802.3af (PoE, Type 1) and IEEE 802.3at (PoE+, Type 2) compliant PSE portsPoE Max Power per Port (at PSE) 30 W MaxPoE Power Budget (at PSE) 90 WPort 1 (LAN1), af/at compliant PD port4G LTE Cat 4 up to 150 DL/50 UL MbpsChanges.
poe.budgetW: 90(source URL recorded), soshow power inlinenow allocates.wwan1300M->150M. A Cat 4 radio cannot reach 300 Mbps; 300M is this family's Cat 6 figure (RUT260, RUT360, RUTX11). The vendor prints 150 DL/50 UL, the same reading #2160 applied to the UMR rows.sourceUrlpointed at/product/rut951/, which redirects to the non-PoE RUT951 page. Now/products/routers/rut951-poe.The 90 W is conditional, and the note says so. The datasheet's power-source table: PoE+ (802.3at Type 2) input ->
limited PoE output - up to 15 W total (1 port IEEE 802.3af Type 1); 802.3af input or DC below 44 V ->No PoE output available; DC >44 V and >=100 W ->Full PoE+ operation - up to 90 W total (3 ports IEEE 802.3at Type 2). The engine holds one static budget, so the published ceiling is recorded and the conditions live inpoe.note/notes, the treatment the AT-X530DP supply-dependent budgets already use. A lab on a sub-44 V supply gets 0 W in the field and 90 W in the model - stated, not hidden.After:
Sources: https://www.teltonika-networks.com/products/routers/rut951-poe (200, 3,082,884 B -
Total power budget of 90W,four PoE+ Ethernet ports); https://solwise.co.uk/downloads/files/Datasheet_RUT951%20PoE+_1.06_19-02-2026.pdf (200, application/pdf, 3,875,741 B, 15 pp - every port and power row above). Teltonika hosts no stable public PDF path for this model (/files/datasheets/...answers its 404 page), so the distributor mirror of the vendor datasheet is cited by checksummed size and page count.Gates:
syntax-check474 files OK;audit-port-typesno contradictions;audit-poe-budgetsilent rows 99 -> 98 (and prose-but-unmodelled 23 -> 22);hardware-invariants26 passed;poe21 passed;run-tests394 suites / 13,203 assertions, 0 failed.DEVICE_REGISTRY.mdregenerated, unchanged.