Refs #130 (does not close it - the Pro's census is still unpublished; this is the catalogue defect found underneath the request).

What was wrong

isPoePd() in engine/media.js matches unifi in a device's model/label and infers a 12.95 W 802.3af draw on any copper port the spec leaves silent. Four UXG rows said nothing about power, so each of their RJ45 sockets was a powered device:

row phantom draw vendor's power method
uxg-lite.json eth0, eth1 - 25.9 W USB type C (5V DC/3A)
uxg-max.json eth0-eth4 - 64.75 W USB type C (5V DC/3A)
uxg-enterprise.json eth0, eth1 - 25.9 W Universal AC input, (2) hot-swappable 150W CRPS
uxg-fiber.json eth0-eth4 - 64.75 W DC jack (54V DC/1.1A)

None of the four accepts PoE on any port. A lab that cables one of these to a PoE switch would see the switch's budget spent on a gateway running off a wall wart. Same correction as uxg-pro.json (#2118) and udm-pro-max.json (#2111).

Evidence

Sources read 2026-11-19, all Ubiquiti-hosted:

  • https://techspecs.ui.com/unifi/cloud-gateways/uxg-lite - 200, 643,116 B. Port Layout: 1 GbE RJ45 x2 (1G/100M/10M); Max. WAN 1; Default WAN (1) GbE RJ45; Max. Power Consumption 3.83 W; Power Method USB type C (5V DC/3A).
  • https://techspecs.ui.com/unifi/cloud-gateways/uxg-max - 200, 647,803 B. Port Layout: 2.5 GbE RJ45 x5 (2.5G/1G/100M/10M); Max. WAN 4; Max. Power Consumption 9.6 W; Power Method USB type C (5V DC/3A).
  • https://techspecs.ui.com/unifi/cloud-gateways/uxg-enterprise - 200, 671,598 B. Port Layout: 2.5 GbE RJ45 x2, 10G SFP+ x2 (10G/1G), 25G SFP28 x2 (25G/10G/1G); Max. WAN 5; Max. Power Consumption 82 W; Power Method Universal AC input, 100-240V AC, 7A Max.; Power Supply (2) hot-swappable 150 W CRPS.
  • https://techspecs.ui.com/unifi/cloud-gateways/uxg-fiber - 200, 649,433 B. Port Layout: 2.5 GbE RJ45 x4, 10 GbE RJ45 x1 (10G/2.5G/1G), 10G SFP+ x2 (10G/1G); Max. WAN 6; Max. Power Consumption 25 W excluding PoE; Power Method DC jack (54V DC/1.1A).
  • Store pages confirm the PoE fields are absent rather than unread: store.ui.com/us/en/products/uxg-lite (200, 534,758 B), .../uxg-max (200, 525,162 B), .../uxg-enterprise (200, 539,028 B) each carry PoE Budget: flag Empty and repeat the power method quoted above.

Port counts were re-checked against the same pages and are unchanged - only the power claim moves.

Deliberately not modelled: the Fiber's 30 W PoE+ port

uxg-fiber does source power: techspecs prints PoE Budget 30 W and Max. PoE Wattage per Port by PSE - PoE+ 30 W at 50-57 V, and store.ui.com/us/en/products/uxg-fiber (200, 476,760 B) says "Integrated 4-port switch with (1) PoE+ port". So one of the four 2.5G RJ45 ports is a 30 W PSE - but Ubiquiti does not say which one, and publishes no datasheet for the SKU (the store payload carries datasheet: null; dl.ui.com/ds/uxg-fiber_ds.pdf lands on the 609,911-byte techspecs front page). Naming a port would be a guess; declaring the 30 W budget with no PSE port fails test/poe-inference.test.js ("a device that claims a budget with no port to source it"). Both stay unwritten, and the open field is recorded in the row's notes.

Traps recorded

dl.ui.com/ds/{uxg-lite,uxg-max,uxg-enterprise,uxg-fiber}_ds.pdf all resolve to https://techspecs.ui.com/, 609,911 B, text/html - that is the datasheet miss, not a datasheet. The hyphenated key worked for uxg-pro only because that SKU has a published PDF.

Gates

  • node scripts/syntax-check.js - 445 files, all OK
  • node scripts/audit-port-types.js - 2356 models, 0 offending ports
  • node test/hardware-invariants.test.js - 26 passed, 0 failed
  • node test/import-devices-capabilities.test.js - 34 passed, 0 failed
  • node test/poe-inference.test.js - 17 passed, 0 failed
  • node scripts/regen-registry-doc.js - no diff (no device added or removed)
Refs #130 (does not close it - the Pro's census is still unpublished; this is the catalogue defect found underneath the request). ## What was wrong `isPoePd()` in `engine/media.js` matches `unifi` in a device's model/label and infers a 12.95 W 802.3af **draw** on any copper port the spec leaves silent. Four UXG rows said nothing about power, so each of their RJ45 sockets was a powered device: | row | phantom draw | vendor's power method | |---|---|---| | `uxg-lite.json` | eth0, eth1 - 25.9 W | USB type C (5V DC/3A) | | `uxg-max.json` | eth0-eth4 - 64.75 W | USB type C (5V DC/3A) | | `uxg-enterprise.json` | eth0, eth1 - 25.9 W | Universal AC input, (2) hot-swappable 150W CRPS | | `uxg-fiber.json` | eth0-eth4 - 64.75 W | DC jack (54V DC/1.1A) | None of the four accepts PoE on any port. A lab that cables one of these to a PoE switch would see the switch's budget spent on a gateway running off a wall wart. Same correction as `uxg-pro.json` (#2118) and `udm-pro-max.json` (#2111). ## Evidence Sources read 2026-11-19, all Ubiquiti-hosted: - `https://techspecs.ui.com/unifi/cloud-gateways/uxg-lite` - 200, 643,116 B. Port Layout: **1 GbE RJ45 x2 (1G/100M/10M)**; Max. WAN 1; Default WAN (1) GbE RJ45; Max. Power Consumption 3.83 W; Power Method **USB type C (5V DC/3A)**. - `https://techspecs.ui.com/unifi/cloud-gateways/uxg-max` - 200, 647,803 B. Port Layout: **2.5 GbE RJ45 x5 (2.5G/1G/100M/10M)**; Max. WAN 4; Max. Power Consumption 9.6 W; Power Method **USB type C (5V DC/3A)**. - `https://techspecs.ui.com/unifi/cloud-gateways/uxg-enterprise` - 200, 671,598 B. Port Layout: **2.5 GbE RJ45 x2, 10G SFP+ x2 (10G/1G), 25G SFP28 x2 (25G/10G/1G)**; Max. WAN 5; Max. Power Consumption 82 W; Power Method **Universal AC input, 100-240V AC, 7A Max.**; Power Supply (2) hot-swappable 150 W CRPS. - `https://techspecs.ui.com/unifi/cloud-gateways/uxg-fiber` - 200, 649,433 B. Port Layout: **2.5 GbE RJ45 x4, 10 GbE RJ45 x1 (10G/2.5G/1G), 10G SFP+ x2 (10G/1G)**; Max. WAN 6; Max. Power Consumption 25 W excluding PoE; Power Method **DC jack (54V DC/1.1A)**. - Store pages confirm the PoE fields are absent rather than unread: `store.ui.com/us/en/products/uxg-lite` (200, 534,758 B), `.../uxg-max` (200, 525,162 B), `.../uxg-enterprise` (200, 539,028 B) each carry **PoE Budget: flag Empty** and repeat the power method quoted above. Port counts were re-checked against the same pages and are unchanged - only the power claim moves. ## Deliberately not modelled: the Fiber's 30 W PoE+ port `uxg-fiber` **does** source power: techspecs prints **PoE Budget 30 W** and **Max. PoE Wattage per Port by PSE - PoE+ 30 W** at 50-57 V, and `store.ui.com/us/en/products/uxg-fiber` (200, 476,760 B) says *"Integrated 4-port switch with (1) PoE+ port"*. So one of the four 2.5G RJ45 ports is a 30 W PSE - but Ubiquiti does not say **which** one, and publishes no datasheet for the SKU (the store payload carries `datasheet: null`; `dl.ui.com/ds/uxg-fiber_ds.pdf` lands on the 609,911-byte techspecs front page). Naming a port would be a guess; declaring the 30 W budget with no PSE port fails `test/poe-inference.test.js` ("a device that claims a budget with no port to source it"). Both stay unwritten, and the open field is recorded in the row's notes. ## Traps recorded `dl.ui.com/ds/{uxg-lite,uxg-max,uxg-enterprise,uxg-fiber}_ds.pdf` all resolve to `https://techspecs.ui.com/`, 609,911 B, `text/html` - that is the datasheet *miss*, not a datasheet. The hyphenated key worked for `uxg-pro` only because that SKU has a published PDF. ## Gates - `node scripts/syntax-check.js` - 445 files, all OK - `node scripts/audit-port-types.js` - 2356 models, 0 offending ports - `node test/hardware-invariants.test.js` - 26 passed, 0 failed - `node test/import-devices-capabilities.test.js` - 34 passed, 0 failed - `node test/poe-inference.test.js` - 17 passed, 0 failed - `node scripts/regen-registry-doc.js` - no diff (no device added or removed)
devices(ubiquiti): the UXG family is USB-C/AC powered, not PoE-powered (refs #130)
All checks were successful
CI / Classify the change (pull_request) Successful in 12s
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 9s
CI / Server smoke test (pull_request) Has been skipped
CI / Docker build (pull_request) Has been skipped
CI / Test (Node 20) (pull_request) Successful in 52s
CI / Test (Node 22) (pull_request) Successful in 53s
CI / Test (Node 18) (pull_request) Successful in 57s
CI / Arm auto-merge (pull_request) Successful in 4s
aa1ccfe757
All four rows matched isPoePd()'s 'unifi' text match and drew 12.95 W of
802.3af on every copper port - 25.9 W on the Lite, 64.75 W on the Max and
Fiber, 25.9 W on the Enterprise - on boxes the vendor powers from a USB-C
5 V/3 A adapter, dual 150 W CRPS AC supplies and a 54 V DC jack.

Each copper port now says poeIn: false, and the notes cite the tech-spec
Port Layout / Max. WAN Port Count / Power Method rows and the store page
whose PoE Budget field is flagged Empty.
forgejo-actions scheduled this pull request to auto merge when all checks succeed 2026-11-19 08:26:58 +00:00
jaylouisw deleted branch catalogue/1119-0822 2026-11-19 08:41:08 +00:00
Sign in to join this conversation.
No reviewers
No milestone
No project
No assignees
1 participant
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".

No due date set.

Dependencies

No dependencies set.

Reference
jaylouisw/packetforge!2121
No description provided.