The defect. A row that declares
poe-pseand carriespoeOutports but nopoe.budgetWis not a box with an unknown budget:engine/simulator.jsopens withif (!dev.poeBudget) continue;, so the PSE is skipped, nothing on it can be powered, andshow power inlinehas no allocation to report. Four UniFi cloud gateways were in that state while the vendor's own spec table printed a budget for each.devices/ubiquiti/udr.jsonPoE Budget = 40W,PoE = 15.4W,44-57V1 GbE RJ45 = 5 (2 PoE)poeOut, no budgetdevices/ubiquiti/udr7.jsonPoE Budget = 15.4W,PoE = 15.4W,44-57V2.5 GbE RJ45 = 4 (1 PoE)poeOut, no budgetdevices/ubiquiti/udm-se.jsonPoE Budget = 180W,PoE = 15.4W,PoE+ = 30W(6) PoE+(2) PoE+poeOut, no budget, nosourceUrlat alldevices/ubiquiti/ucg-industrial.jsonPoE Budget = DC input: 270W / ATX power: 75W,PoE+ = 30W,PoE+++ = 90W2 PoE+++, 2 PoE+,1 PoE+++poeOut, no budgetSources, read 2026-11-19 off each product's rendered spec table (
__NEXT_DATA__->pageProps.product.technicalSpecification, i.e. the table on the page):Two of them are cross-read against the datasheet text layer so the number does not rest on one surface: https://dl.ui.com/ds/udr_ds.pdf (200, 771,202 B, 3 pp) prints
PoE budget 40WbesidePoE interface (2) PoE (Pair B 4, 5+; 7, 8-)andMax. PoE wattage per port by PSE 15.4W; https://dl.ui.com/ds/udm_se_ds.pdf (200, 358,669 B, 3 pp) prints the PoE/PoE+ placement and per-port maxima but no aggregate, which is why the 180 W is cited to the spec table and the placement to the sheet. UCG-Industrial's 270 W is the DC-input ceiling with the ATX figure (75 W) inpoe.note, the same convention asdevices/allied-telesis/at-x530dp-28ghxm.json. Nopoe.perPortWis written: each PSE port already carries itspoeOutClass, and a single number cannot describe a mixed box (UDM-SE is 6 x 15.4 W + 2 x 30 W).Deliberately left alone.
devices/ubiquiti/ucg-fiber.jsonprintsPoE Budget = 30Won the same table and marks no port PoE in it; its document list holds only{"type":"InstallationGuide","url":"https://ui.com/qig/ucg-fiber"}, anddl.ui.com/ds/ucg-fiber.pdf,ucg-fiber_ds.pdfanducgf_ds.pdfall 302 to the techspecs root. A budget with no PSE port is the conditionscripts/audit-poe-budget.jsrefuses, and apoeOutport the vendor has not marked would be invented. The exact missing field - which of the five RJ45 ports sources PoE, at which class - is recorded in the research note.research/ubiquiti-cloud-gateway-poe-budgets.mdholds the full 17-row table and the two method traps (theMax. PoE Wattage per Port by PSEfeature exists with no value on all five pages;product.datasheetisnulleven where a datasheet exists, soproduct.documentsis the pointer).Gates
node scripts/syntax-check.js- 442 files, all OKnode scripts/audit-port-types.js-No port contradicts its declared type.node scripts/audit-poe-budget.js- 112 -> 108 of 402 PSEs cannot be asked how much they supply;Budget with no PSE port ... 0node scripts/import-devices.js --dry-run- nothing written; its refusals are the pre-existingpeplink/MAX-BR1-PRO-5Gandzte/F8648Pduplicates inresearch/incoming, not these rowsnode scripts/run-tests.js- 363 suites, 12,397 assertions, 0 failednpm run regen:registry-doc- catalogue pages current, no diffOn #130 itself: no Ubiquiti source names a UDW-PRO; the Pro surfaces were measured to exhaustion on earlier passes and were not re-walked here. This entry stays open.