research: Huawei's Info-Finder answers without a login and then refuses every product (#807) #1889
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!1889
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1117-1955"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #807. Not a close — no port, slot or board figure is added to the catalogue, because the pass found none.
1. The vendor names Info-Finder as the board-spec surface.
https://support.huawei.com/enterprise/zh/doc/EDOC1100447312(200,text/html, 471,294 B) is 企业光网络资料获取指南V1.0, a public infographic: "光产品Info-Finder … 对比产品/单板/软件规格差异". Board-level spec comparison, on a Huawei host — the tool that would answer all four E9600 requests.2. The zh support locale is a second document list, larger and no more open.
…/zh/optical-transmission/optixtrans-e9605-pid-250732995(200, 430,883 B) links 136 uniqueEDOCids; 58 answer 200, versus 39 on the English page. 57 of the 58 are video/article titles; the one document is the infographic above. Chinese docs have their own ids (EDOC1100621489vsEDOC1100621488) and are equally gated, with or without the page'sidPath=query — so the earlier "404s are not a URL-shape problem" reading holds on a second id family.3. The API is anonymous and then refuses everything. The SPA (
…/info-finder/vue/en/enterprise/index, 200, 5,804 B; the bare/info-finder/301-loops) is axios againstbaseURL /info-finder.POST /speccenter/v2/getSpecBoardsaccepts{"domain":"0","language":"en","pbiId":…}and returns10003 outchain mapping pbiIdMd5 not uniquefor E9605250732995, E9612250733000, E9624250733004, E9624X251792361, the series offering265949421— and for a CloudEngine S6730-H24X6C control (250538959), so the fault is global, not an E9600 gap.domain:"1"(zh) returns10110 用户的权限不足— login required.Missing field, unchanged: one client/tributary board's port census (
TNG1N206,TNG1A212,TNG1T212orTNG1M210D), orEDOC1100163901/EDOC1100621488from a session with the right to paste it.Also included:
research/vendor-soft-200-hosts.md—dl.ui.comanswers any path (including a nonsense one) with 200 and the same 609,911-byte HTML shell, so a 200 on a.pdfpath is not a document. Method note; no issue claim.Gates:
node scripts/syntax-check.js(393 files OK),audit-port-types.js(no port contradicts its declared type),check-control-bytes.js(clean),test/hardware-invariants.test.js(26 passed, 0 failed).The zh support locale is a second, larger document list (136 ids, 58 public vs 39 on the English page) and adds no board chapter: 57 of the 58 are video/article titles and the one document is a marketing infographic, EDOC1100447312, which names Info-Finder as the place Huawei publishes board-level spec comparisons. That tool is a Vue SPA over an anonymous JSON API (/info-finder/speccenter/v2/getSpecBoards, baseURL /info-finder). Payload shape established by probing: {domain:'0',language,pbiId}. It reaches the data layer and fails for every product tested - the four E9600 pids and a CloudEngine S6730-H24X6C control - with 10003 'outchain mapping pbiIdMd5 not unique'; domain '1' wants a login (10110). So the board census is still unsourced, and the route is now closed by measurement instead of by guess. Second file records a probe-method failure: dl.ui.com answers any path with 200 and the same 609,911-byte HTML shell, so a 200 on a .pdf path proves nothing.