research(oceanprotect): both E8000 enumeration routes are account-gated, and both are now measured #1873
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!1873
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1117-1655"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #742 - this PR records measurements; it does not close the issue.
Issue #742 (Huawei OceanProtect E8000) has been parked on one field: the interface-module slots per controller and the ports on each module type.
research/oceanprotect-x-series-port-census.mdranked two routes as still untried - Spare Parts Query, and one rendered section of the E8000 book. Both were measured this pass.1. The document tree needs a Huawei account, at the service
GET https://support.huawei.com/supportgateway/view/v1/enterprise/doc/catalogue?nid=EDOC1100486186-> 401Crawler UA gets that JSON; browser UA gets Akamai 403. So 403 is the edge and 401 is the document service, i.e. the endpoint is reachable and wants a session. The body is gzipped whatever
Accept-Encodingsays, so it reads as an empty 91-byte response withoutcurl --compressed- which is how a previous pass could record "no answer" here.Consequence: there is no anonymous enumeration entry point for revision-scoped topic hashes. A book renders only when a hash is already indexed by a search engine - which is why the X3000 V200R001 Product Description (
EDOC1100368234/8587c2ff/overview) renders andEDOC1100486186does not.2. Spare Parts Query: public CSRF token, private data
https://info.support.huawei.com/storage/spareparts/is public (200, bundlemain-ZCQDDWQH.js, 2,605,430 B) and names its call:{API_HOST}/storage-gw/rest/itcms/getDataList?appId=spare&dataSetId=SpareParts_Product_Output&nodeId=SpareParts_Product_Output&lang=en&child=true.GET /storageinfogw/csrf-gw/rest/csrf/getCsrfTokenGET .../getDataList?appId=spare...withCsrf-Token/X-Csrf-Token/csrf-tokenlang: enGET /storageinfo-gw-v2/csrf-gw/rest/csrf/getCsrfTokenSpecifications Query (the route recorded for #743,
main-H3SH7DII.js, 2,775,994 B) uses the sameAPI_HOST/API_HOST_V2pair, so one measurement covers both tools.3. The E8000 data sheet, re-fetched: still no census
scripts/huawei-material-fetch.jsresolved the V200R001C20 data sheet from the material page: 2,407,538 B, 4 slides. Slide 3 carries 2 controllers per node, up to 128 nodes, 2 PiB/node, port types16/32/64 Gbit/s Fibre Channel; 10/25/40/100GE, enclosure dimensions. Keyword counts over the whole deck:slot0,interface module0,IOM0,port1.Also recorded so nobody borrows it: the 820 mm controller-enclosure depth coincides with the X6000/X8000 2 U 25-disk enclosure, but equal depth is not a shared backplane - the one document naming all three (EDOC1100305200, Parts Replacement) only makes the 2 U fan module and smart disk enclosure shared FRUs. Six IOM slots imported on that basis would be the Dorado-Table-6-1 error again.
What would close #742
One rendered section of
EDOC1100486186(Product Description),EDOC1100485347(Quick Installation Guide, dated 2026-09-30 on Huawei's own product page) orEDOC1100486185(Installation Guide) pasted by a reader with a support session; or a stated configuration such as "E8000 node, 2 controllers, 2 x 4-port 25GE IOM per controller".Gates
node scripts/syntax-check.js- 391 files, all OKnode scripts/audit-port-types.js- no port contradicts its declared typenode scripts/check-control-bytes.js- cleannode test/hardware-invariants.test.js- 26 passed, 0 failednode test/request-queue.test.js- 23 passed, 0 failednode scripts/check-doc-citations.js- exit 0npm run regen:registry-doc- registry section rewritten fromresearch/open-device-requests.jsondevices/spec changed in this PR