research: E6600 chassis chapters download anonymously, and hold no board census (#803) #1826

Merged
jaylouisw merged 1 commit from catalogue/1117-0955 into main 2026-11-17 10:04:30 +00:00
Owner

Refs #803 (does not close it: the port census is still missing).

New route, verified today. The per-chapter product documentation is reachable without a login once the 32-hex material hash is known: https://e.huawei.com/en/documents/others/<hash> is server-rendered and prints the e-file.huawei.com asset path in its HTML, so the 19-digit asset token never has to be guessed.

What that fetched. (2)-OptiXtrans E6616-Datasheet = OptiXtrans E6600 V100R025C10 Product Documentation, 20 pp, 1,535,511 B, issue 2026-03-31. Chapter 1 gives the slot layout verbatim:

  • DC chassis: service slots 1-14 (14), system control 15/16, DC power 17-18, fan 19.
  • AC chassis: service slots 2, 4, 5-14, printed as 12/10 - 1500 W AC chassis (dual power supply modules): 12; 2400 W AC chassis (four power supply modules): 10; AC power 1 and 3 or 1-4 for TMB1APIU; fan 19.

The trap it closes. The public spec table prints "AC chassis: 12"; the 2400 W AC chassis actually has 10 service slots, because four slots carry TMB1APIU boards. Any future E6616/E6616X label must name the power configuration.

What it does not contain. No service-board census: the only boards named are system control/cross-connect (TMK5SXCH, TMK5XCH, TMK6XCH, TMK5UXCME, TMK5XCS), fgOTN (TMK1FXCL, TMK1XCL), power TMB1APIU and fan TMK5FAN. Section 1.5 is per-slot backplane capacity, not ports. The E6600 partner mirror covers E6608T/E6608/E6616 only - not the X. So #803 still needs the service-board part number per slot plus its front-panel port census.

scripts/huawei-material-fetch.js makes that lookup repeatable (hash in, PDF out), so the next pass needs one search hit for a TMB1*/TMK1* chapter rather than a full re-walk.

Gates: syntax-check 384 files OK; audit-port-types no contradictions; check-node-surface clean; check-control-bytes clean; hardware-invariants 1/1 pass; registry doc regenerates with no diff.

Refs #803 (does not close it: the port census is still missing). **New route, verified today.** The per-chapter product documentation is reachable without a login once the 32-hex material hash is known: `https://e.huawei.com/en/documents/others/<hash>` is server-rendered and prints the `e-file.huawei.com` asset path in its HTML, so the 19-digit asset token never has to be guessed. **What that fetched.** `(2)-OptiXtrans E6616-Datasheet` = *OptiXtrans E6600 V100R025C10 Product Documentation*, 20 pp, 1,535,511 B, issue 2026-03-31. Chapter 1 gives the slot layout verbatim: - DC chassis: service slots **1-14** (14), system control **15/16**, DC power **17-18**, fan **19**. - AC chassis: service slots **2, 4, 5-14**, printed as 12/10 - *1500 W AC chassis (dual power supply modules): 12; 2400 W AC chassis (four power supply modules): 10*; AC power 1 and 3 or 1-4 for `TMB1APIU`; fan 19. **The trap it closes.** The public spec table prints "AC chassis: 12"; the 2400 W AC chassis actually has **10** service slots, because four slots carry `TMB1APIU` boards. Any future E6616/E6616X label must name the power configuration. **What it does not contain.** No service-board census: the only boards named are system control/cross-connect (`TMK5SXCH`, `TMK5XCH`, `TMK6XCH`, `TMK5UXCME`, `TMK5XCS`), fgOTN (`TMK1FXCL`, `TMK1XCL`), power `TMB1APIU` and fan `TMK5FAN`. Section 1.5 is per-slot backplane capacity, not ports. The E6600 partner mirror covers E6608T/E6608/E6616 only - not the X. So #803 still needs the service-board part number per slot plus its front-panel port census. `scripts/huawei-material-fetch.js` makes that lookup repeatable (hash in, PDF out), so the next pass needs one search hit for a `TMB1*`/`TMK1*` chapter rather than a full re-walk. Gates: `syntax-check` 384 files OK; `audit-port-types` no contradictions; `check-node-surface` clean; `check-control-bytes` clean; `hardware-invariants` 1/1 pass; registry doc regenerates with no diff.
research: E6600 chassis chapters download anonymously, and hold no board census (#803)
All checks were successful
PR rebase / Rebase onto main and arm auto-merge (pull_request) Successful in 6s
CI / Classify the change (pull_request) Successful in 11s
CI / Server smoke test (pull_request) Successful in 7s
CI / Docker build (pull_request) Successful in 24s
CI / Test (Node 20) (pull_request) Successful in 50s
CI / Test (Node 18) (pull_request) Successful in 56s
CI / Test (Node 22) (pull_request) Successful in 54s
CI / Arm auto-merge (pull_request) Successful in 16s
7758915a38
The E6616 chassis chapter of OptiXtrans E6600 V100R025C10 is reachable without a login once the 32-hex material hash is known: the material page at e.huawei.com/en/documents/others/<hash> prints the e-file.huawei.com asset path in its HTML. Fetched that way today (1,535,511 bytes, 20 pages) it gives the slot layout verbatim - DC service slots 1-14, system control 15/16, power 17-18, fan 19; AC service slots 2, 4, 5-14 with the 1500 W chassis at 12 and the 2400 W chassis at 10 - and confirms the chapter set carries no service-board census, so #803 stays blocked on the board part number per slot. Adds scripts/huawei-material-fetch.js to make the lookup repeatable.
Sign in to join this conversation.
No reviewers
No milestone
No project
No assignees
1 participant
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".

No due date set.

Dependencies

No dependencies set.

Reference
jaylouisw/packetforge!1826
No description provided.