catalogue(oceanprotect): the X8000 front-end census is published - 4 ports per interface module (#741) #1797
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!1797
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1117-0555"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #741 (does not close it: the family's X9000 half is still blocked, see below).
What changed
Three passes parked issues #741/#742/#743 on the same sentence: Huawei publishes front-end port types and a controller count, never a port count. That is true of the datasheets and of the marketing spec tables. It is false of the Product Description's interface-module chapters, which are ordinary indexed sections.
Slot geometry, OceanProtect X6000, X8000 1.3.0 Installation Guide (with Data Backup Feature), Cabinet Layout and Connection Planning - https://support.huawei.com/enterprise/en/doc/EDOC1100318730/ce945100/cabinet-layout-and-connection-planning :
The spec
devices/huawei/oceanprotect-x8000.json- 2 U controller enclosure, controllers A and B, a 4-port 10GE electrical module in IOM 0 and another in IOM 1 on each controller: 16 x 10GbE SFP+, no PoE,nas, capabilitieshost/http-server/cli.Deliberately not modelled, with the reason in
notes: IOM 4 (optional, and the two versions of the slot rules served on that one page disagree about it - the earlier block puts 12 Gbit/s SAS modules in IOM 5 > 4 > 3, the data-backup block allows front-end modules in IOM 4); the IOM 2 RDMA and IOM 3 RoCE modules (internal / inter-enclosure, "no cable connection is required"); the SAS disk-expansion modules; and the management network port, whose count and rate appear only in a figure. The SmartIO family is not modelled at all: its page says only that it "has the same appearance" as the 10GE electrical module, and a faceplate is not a port census.Why #741 stays open
The X9000 half has no live source. Today:
/enterprise/en/doc/EDOC1100337685/8ed1346b/overview(X9000 1.5.0 PD) - Googlebot UA: 302 -> 404/view/notFound; browser UA: 403..../67ea5a63/interface-module,.../ad9f2760/component-description- 404.info.support.huawei.com/enterprise/en/doc/EDOC1100337685/8ed1346b/overview- 200 but lands on/supportindex/, not the document./enterprise/{es,de}/doc/EDOC1100337685/...- 404 (locale variants do not help).EDOC1100368229(X9000, X9100 1.6.0-1.7.0 & V200R001 PD),EDOC1100305237(X9000 Quick Installation Guide),EDOC1100368334(X9000 Hardware Installation Guide) - all 404 at the doc root, and no section slug of any of them is indexed.The 4 U 28-slot geometry is still visible in search caches, and it is also printed almost verbatim by a live page -
EDOC1100484689/bb36e2c- whose real title is OceanStor Dorado 8000 and Dorado 18000 V700R001 Site Planning Guide. That is another product's census and is not imported here.What closes #741: one live section of
EDOC1100368229orEDOC1100368334, or one stated X9000 configuration (controller count, front-end slots, module mix).research/oceanprotect-x-series-port-census.mdcarries all of the above, including the HTTP status of every URL tried, so the next pass does not re-walk it.Gates
node scripts/syntax-check.js- 376 files, all OKnode scripts/audit-port-types.js- "No port contradicts its declared type"PF_INCOMING,--dry-runthen--apply) - 1 spec added, 0 duplicates, 0 rejected, no capability warningsnode test/hardware-invariants.test.js- 26 passed, 0 failed (2,345 models)node test/spec-vs-description.test.js- 3 passed;node test/faceplate-catalogue.test.js- 14 passednode scripts/regen-registry-doc.js- 2,345 models / 29,107 sockets / 963 shapes written across 5 pages