research(huawei): the E8000 datasheet is a PowerPoint, and it has no port census either (#742) #1785
No reviewers
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
jaylouisw/packetforge!1785
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "catalogue/1117-0355"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Refs #742 - research only; this does not close the request.
#742 asks for the OceanProtect E8000 node and its ports. This pass went after the one source the X-series requests did not have - the datasheet - and it settles the E8000 half of the question without unblocking it.
The datasheet exists, and it is a PowerPoint.
https://e.huawei.com/en/products/storage/oceanprotect/oceanprotect-e8000(200, 343,723 bytes) links a download wrapper (.../documents/products/storage/597eb7d1363f4b5da0d4ad663da1f7b6); itsattachmentUrlis.../marketingcloud/pep/asset/20000001/Material/597eb7d1363f4b5da0d4ad663da1f7b6/M3T1A590N1325408746781700176/Huawei%20OceanProtect%20E8000%20Backup%20and%20Archiving%20Converged%20Storage%20V200R001C20%20-%20Data%20Sheet.pptx(200, 2,407,538 bytes, pptx). Slide 3 gives:No port-count row, no interface-module table, no slot count. The page's "2 U 36-slot high-density hardware" is the disk slot count, not a port census.
Two new access facts
https://support.huawei.com/hedex/api/navi/EDOC1100486186/first-level-tree->401 {"status":401,"message":"NOT LOGIN!"}. The SPA's JSON navigation endpoints are the one gated part of the site.EDOC1100318730/ce945100(200, 567,916 bytes) carries 31 section links - so one indexed section of the E8000 V200R001 set would open the whole set. None is indexed;EDOC1100486186andEDOC1100486185still 404 at the doc root, and the previously indexedEDOC1100305200/6cc495b9now 404s too (1.x superseded).The trap this pass avoided: the accessible 1.3.0 guide states "each of controllers A and B provides six interface module slots ... front-end modules only in IOM 0, 1 and 4". That is the X6000/X8000 1.3.0 Installation Guide and the E8000 is a different enclosure (86.1 x 447 x 820 mm NVMe controller enclosure). Borrowing it would be the same family-sibling error as the Dorado 8000 Table 6-1 trap already recorded.
Changed:
research/oceanprotect-x-series-port-census.mdonly. No catalogue entry, no engine change - there is no port census to land.Gates:
syntax-check.js374 files OK;audit-port-types.jsno contradiction;test/hardware-invariants.test.js26 passed, 0 failed;check-control-bytes.jsclean.Exact missing field: interface modules per controller, which slots take front-end modules, and each module's port count - or one base ordering line ("E8000 node, 2 controllers, 2 x 4-port 25GE module per controller").
33b9f7496b064d66f176